The design of a ZIMM bevel gearbox of the ZK Series is influenced by the operating factor fb, temperature factor ft, duty factor fe and speed factor fd. These factors are used in the calculations for design torque, design power and thermal limit power. The operating factor takes into account application case, operating time and starts per hour. Temperature factor, duty factor and speed factor are determined via table values.
Which temperature factors apply when designing a ZIMM bevel gearbox of the ZK Series?
The temperature factor ft is determined via the ambient temperature.
| Ambient temperature [°C] | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 |
| Temperature factor ft | 0,90 | 0,95 | 1,00 | 1,10 | 1,20 | 1,30 | 1,40 | 1,50 | 1,60 |
Which duty factors apply when designing a ZIMM bevel gearbox of the ZK Series?
The duty factor fe is determined via the maximum duty factor in percent per 10 minutes.
| Max. duty factor [% / 10 min] | 100 | 80 | 60 | 40 | 20 | 10 |
| Duty factor fe | 1,00 | 0,95 | 0,80 | 0,60 | 0,30 | 0,15 |
Which speed factors apply when designing a ZIMM bevel gearbox of the ZK Series?
The speed factor fd is determined via the input speed nD.
| Input speed nD [min⁻¹] | 0–500 | 500–1000 | 1000–1700 | 1700–2400 | 2400–3000 |
| Speed factor fd | 0,90 | 1,00 | 1,15 | 1,23 | 1,30 |